SRK35ZS-WFB / SRC35ZS-W2

WALL MOUNTED : 3.5(0.9~4.0)

Indoor Unit – SRK35ZS-WFB / Outdoor Unit – SRC35ZS-W2
Nominal cooling capacity of 3.5kW

Description

Indoor unit SRK35ZS-WFB
Outdoor unit SRC35ZS-W2
Power source 1Phase, 220 – 240, 50Hz
Nominal cooling capacity (Min~Max) kW 3.5(0.9~4.0)
Nominal heating capacity (Min~Max) kW 4.0(0.9~5.0)
Power consumption Cooling/Heating kW 0.89 / 0.94
EER/COP Cooling/Heating 3.93 / 4.26
Max. running current A 9
Sound power
level
Indoor Cooling/Heating dB(A) 54 / 56
Outdoor Cooling/Heating 61 / 61
Sound pressure
level
Indoor Cooling (Hi/Me/Lo/Ulo) 40 / 30 / 26 / 19
Heating (Hi/Me/Lo/Ulo) 41 / 36 / 25 / 19
Outdoor Cooling/Heating 50 / 48
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 11.3 / 8.7 / 7.0 / 5.0
Heating (Hi/Me/Lo/Ulo) 12.3 / 11.0 / 7.0 / 5.6
Outdoor Cooling/Heating 31.5 / 27.8
Exterior Dimensions Indoor Height x Width x Depth mm 290 x 870 x 230
Outdoor 540 x 780(+62) x 290
Net weight Indoor / Outdoor kg 9.5 / 34.5
Refrigerant Type/GWP R32 / 675
Refrigerant Charge kg/TCO2Eq 0.78 / 0.527
Refrigerant piping size Liquid/Gas ø inch 6.35(1/4″) / 9.52(3/8″)
Refrigerant line (one way) length m Max. 20
Vertical height differences Outdoor is higher/lower m Max. 10 / Max. 10
Outdoor operating
temperature range
Cooling °C -15~46
Heating -15~24
Clean filter Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1
Energy Class (Cooling/Heating) A++/A++
SEER 8.40
SCOP (Average climate) 4.70
Pdesign (cooling/heating(@-10°C)) kW 3.50/3.00
Annual Electricity Consumption (cooling/heating) kWh/a 146/895
Designated Heating Season Average

• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• ‘tonne(s) of CO2 equivalent’ means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281

    Etiam magna arcu, ullamcorper ut pulvinar et, ornare sit amet ligula. Aliquam vitae bibendum lorem. Cras id dui lectus. Pellentesque nec felis tristique urna lacinia sollicitudin ac ac ex. Maecenas mattis faucibus condimentum. Curabitur imperdiet felis at est posuere bibendum. Sed quis nulla tellus.

    ADDRESS

    63739 street lorem ipsum City, Country

    PHONE

    +12 (0) 345 678 9

    EMAIL

    info@company.com

    Cart